Coaxial cables is the best way to fulfill these needs and requirements. Their main purpose in the cabling structures is to transmit data, voice, and video communication. In this regard, our RFC-600-FR coaxial cable is one of the best options. It comes with a special outer jacket made from LSZH (Low Smoke Zero Halogen) material. It is the safest option to be installed in the building structures. The cable is tested and certified from the regulating bodies as it meets or exceeds the performance levels.
Manufacturing Design |
|||
Inner Wire | Material | Solid CCA | |
Diameter (mm) | 4.47 | ||
Minimum Break Strength (N) | 1700 | ||
Insulation | Material | Foamed Polyethylene | |
Diameter (mm) | 11.56 | ||
Centricity (%) | ≥ 85 | ||
Adhesion (@ 25mm) | 10 to 100N | ||
First Outer Conductor | Material | Bonded Aluminum Foil | |
Diameter (mm) | 11.71 | ||
Overlapping % | ≥ 115 | ||
Second Outer Conductor | Material | Tinned Copper Braid | |
Diameter (mm) | 0.18 | ||
No. of Wires | 240 | ||
Jacket Type | Material | LSZH(meets CMR, FT4 rating) | |
Diameter (mm) | 14.99 | ||
Tensile Strength (N/mm2) | ≥ 16.2 | ||
Elongation at break % | ≥ 700 % | ||
Adhesion (@ 50mm) | 20 to 80N | ||
TPE Compound | DW9023B-2C (IEC60332-3) | ||
Smoke Index Test Method | IEC 61034-2 | ||
Toxicity Index Test Method | IEC 60754-2 | ||
Mechanical Features |
|
Minimum Bending Radius (mm) | 38.1 |
Max. Pulling Tension (N) | 1750 |
Crush Resistance of cable (Load of 700N) | < 1% |
Admissible Ambient Temperature (C) | -40 – +85 |
Electrical Features |
|
Impedance (Ω) | 50 |
Capacitance (pF/m) | 77 |
Velocity Ratio (%) | > 87 |
Inner Conductor Wires- DC Resistance (ohm/km) | < 4.60 |
Outer Conductor – DC Resistance (ohm/km) | < 5.40 |
Peak Power rating (Kw) | 40.00 |
Cut Off Frequency (GHz) | 10.30 |
Dielectric Strength (VAC) | 1600.00 |
Insulation Resistance (MΩ/km) | >5,000 |
Voltage Withstand (VDC) | 4000 |
Screening Factor at 1 – 1000MHz (db) | >90 |
Frequency Attenuation (at 20 ℃) |
30 MHz 0.43 dB/100Ft |
50 MHz 0.55 dB/100Ft |
100 MHz 0.85 dB/100Ft |
150 MHz 0.98 dB/100Ft |
220 MHz 1.19 dB/100Ft |
450 MHz 1.71 dB/100Ft |
900 MHz 2.50 dB/100Ft |
1500 MHz 3.32 dB/100Ft |
1800 MHz 3.69 dB/100Ft |
2000 MHz 3.90 dB/100Ft |
2500 MHz 4.42 dB/100Ft |
3000 MHz 5.06 dB/100Ft |
5800 MHz 7.3 dB/100Ft |