Description: –
A horizontal 23 AWG Cat6 cable with a non-plenum jacket. It comes with four shielded twisted pairs of conductor wires. Tested to an extended bandwidth of 550MHz.
Applications: –
It supports all applications of category 6 efficiently. It includes Ethernet 1BASE-TX, 100BASE-VG, and 155 ATMs. Particularly, it is best for high bandwidth applications like 622 ATM, Ethernet 1000BASE-T, Wideband, and all other evolving applications with predicted data rates to 3.2Gbps.
Ratings/Approvals: –
NEC Article 800, UL 1666: CMR Rating FT4, ETL Electrically Verified to ANSI/TIA/EIA 568C.2 Category 6, C (ETL) US, RoHS Compliant.
Construction Layout
- Conductor: 23AWG Solid Bare Copper
- Number of Twisted Pair Wires: 4 Twisted Pairs
- Jacket Material: Polyvinyl Chloride – Low Smoke and Fire-Retardant Material
- Nominal Overall Cable Diameter: 305 in. (7.747 mm)
- Cable Weight: 1000ft. length/ 49lb weight
- Drain: Solid Tin Copper
- Shield: Aluminum/Polyester Tape
- Tape: Clear Mylar Tape
Electrical and Physical Features
- Temperature Rating:
- Installation: 0°C to 50°C
- Operation: -2°C to 60°C
- Velocity of Propagation: 70%
- Mutual Capacitance: 14 pF/ft. Nominal
- Capacitance Unbalance: 330 pF/ft. maximum
- Maximum Conductor D.C.R: 6 Ω/1,000 ft.
- Maximum D.C.R Unbalance: 3%
- Maximum Delay Skew: 18 ns/100m
- Characteristic Impedance:
- From 0.772 MHz – 100 MHz 100Ω± 15%
- From 101 MHz – 250 MHz 100 Ω ± 22%
- From 251 MHz – 550 MHz 100 Ω ± 32%
- Insulation Colors:
- Blue paired with White/Blue
- Orange paired with White/Orange
- Green paired with White/Green
- Brown paired with White/Brown
Electrical Features
| Frequency | Return Loss | Insertion Loss | NEXT | PS- NEXT | ELFEXT | PS- ELFEXT | ACR | PS-ACR |
| MHz | dB(100M) | dB(100M) | dB(100M) | dB(100M) | dB(100M) | dB(100M) | dB(100M) | dB(100M) |
| Minimum | Maximum | Minimum | Minimum | Minimum | Minimum | Minimum | Minimum | |
| 1 | 20.0 | 2.0 | 80.3 | 78.3 | 73.8 | 70.8 | 78.3 | 76.3 |
| 4 | 23.0 | 3.8 | 71.3 | 69.3 | 61.8 | 58.8 | 67.5 | 65.5 |
| 10 | 25.0 | 6.0 | 65.3 | 63.3 | 53.8 | 50.8 | 59.3 | 57.3 |
| 16 | 25.0 | 7.6 | 62.2 | 60.2 | 49.7 | 46.7 | 54.6 | 52.6 |
| 20 | 25.0 | 8.5 | 60.8 | 58.8 | 47.8 | 44.8 | 52.3 | 50.3 |
| 31.25 | 23.6 | 10.7 | 57.9 | 55.9 | 43.9 | 40.9 | 47.2 | 45.2 |
| 62.5 | 21.5 | 15.4 | 53.4 | 51.4 | 37.9 | 34.9 | 38.0 | 36.0 |
| 100 | 20.1 | 19.8 | 50.3 | 48.3 | 33.8 | 30.8 | 30.5 | 28.5 |
| 200 | 18.0 | 29.0 | 45.8 | 43.8 | 27.8 | 24.8 | 16.8 | 14.9 |
| 250 | 17.3 | 32.8 | 44.3 | 42.3 | 25.8 | 22.8 | 11.5 | 9.5 |
| 300 | 16.8 | 36.4 | 43.1 | 41.1 | 24.3 | 21.3 | – – – | – – – |
| 350 | 16.3 | 39.8 | 42.1 | 40.1 | 22.9 | 19.9 | – – – | – – – |
| 400 | 15.9 | 43.0 | 41.3 | 39.3 | 21.8 | 18.8 | – – – | – – – |
| 500 | 14.8 | 49.5 | 40.2 | 38.2 | 20.0 | 17.0 | – – – | – – – |
| 550 | 14.4 | 53.1 | 39.5 | 37.5 | 18.9 | 15.9 | – – – | – – – |
Important Notice: –
In the above table, we iTechCables try to present the most accurate calculations possible. Still, we do not guarantee that they are error-free and 100% accurate. We reserve the right to change this information at any time in the future without notice. Values above 250MHz are for engineering information only.
Packaging Information: –
It is available in 1000ft. length in a convenient EZ-Pull box








Cat6e 23AWG Plenum CMP UTP 100% Bare Copper ETL Listed Cable
Cat6 23AWG Plenum CMP Shielded 100% Bare Copper ETL Listed Cable
Cat6e Riser CMR UTP 100% Bare Copper ETL Listed Cable
Cat6 Riser ETL Listed UTP 100% Bare Copper Outdoor Cable
Cat6 Riser F/UTP CMR Solid Bare Copper ETL Listed Cable
Cat6A Plenum UTP Solid Bare Copper ETL Listed Cable
Cat6e 23AWG Plenum UTP 100% Bare Copper ETL Listed Splineless Cable
Shielded Cat6 Plenum Bare Copper 1000ft Ethernet Cable (Blue)
CAT6A (Augmented) Riser CMR UTP 8C Bare Copper ETL Listed Cable
Cat6 Riser CMR UTP 8C Bare Copper ETL Listed Cable 